Related Experiment Video
Updated: Oct 4, 2026

06:43
Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
[Geomagnetic and artificial weak magnetic fields of superlow frequency as factors changing the body radiosensitivity]
A M Stashkov1, A N Kopylov, I E Gorokhov
1Simferopol State University, Yaltinskaya ul. 4, Simferopol, 333036 Ukraine.
Biofizika
|October 19, 2001
Abstract:
Geomagnetic disturbances and experimentally generated weak variable superlow-frequency magnetic fields have either a radioprotecting or radiosensitizing effect on the mouse body depending on the time, intensity, and mode of influence.
Related Concept Videos
Magnetic Fields
A moving charge or a current creates a magnetic field in the surrounding space, in addition to its electric field. The magnetic field exerts a force on any other moving charge or current that is present in the field. Like an electric field, the magnetic field is also a vector field. At any position, the direction of the magnetic field is defined as the direction in which the north pole of a compass needle points.
A magnetic field is defined by the force that a charged particle experiences...
A magnetic field is defined by the force that a charged particle experiences...
Biological Effects of Radiation
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they produce ions...
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...
Magnetic Susceptibility and Permeability
In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Atomic Nuclei: Magnetic Resonance
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...

