Related Experiment Video
Updated: Aug 7, 2026

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Dose conformity of gamma knife radiosurgery and risk factors for complications
J L Nakamura1, L J Verhey, V Smith
1Department of Radiation Oncology, University of California, San Francisco, CA 94143-0226, USA.
Purpose:
To quantitatively evaluate dose conformity achieved using Gamma Knife radiosurgery, compare results with those reported in the literature, and evaluate risk factors for complications.
Methods And Materials:
All lesions treated at our institution with Gamma Knife radiosurgery from May 1993 (when volume criteria were routinely recorded) through December 1998 were reviewed. Lesions were excluded from analysis for reasons listed below. Conformity index (the ratio of prescription volume to target volume) was calculated for all evaluable lesions and for lesions comparable to those reported in the literature on conformity of linac radiosurgery. Univariate Cox regression models were used to test for associations between treatment parameters and toxicity.
Results:
Of 1612 targets treated in 874 patients, 274 were excluded, most commonly for unavailability of individual prescription volume data because two or more lesions were included within the same dose matrix (176 lesions), intentional partial coverage for staged treatment of large arteriovenous malformations (AVMs) (33 lesions), and missing target volume data (26 lesions). The median conformity indices were 1.67 for all 1338 evaluable lesions and 1.40-1.43 for lesions comparable to two linac radiosurgery series that reported conformity indices of 1.8 and 2.7, respectively. Among all 651 patients evaluable for complications, there were one Grade 5, eight Grade 4, and 27 Grade 3 complications. Increased risk of toxicity was associated with larger target volume, maximum lesion diameter, prescription volume, or volume of nontarget tissue within the prescription volume.
Conclusions:
Gamma Knife radiosurgery achieves much more conformal dose distributions than those reported for conventional linac radiosurgery and somewhat more conformal dose distributions than sophisticated linac radiosurgery techniques. Larger target, nontarget, or prescription volumes are associated with increased risk of toxicity.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...