Related Experiment Video
Updated: Jul 18, 2026

Microdialysis of Ethanol During Operant Ethanol Self-administration and Ethanol Determination by Gas Chromatography
Published on: September 5, 2012
Determination of midazolam in human plasma by solid-phase microextraction and gas chromatography/mass spectrometry
G Frison1, L Tedeschi, S Maietti
1Forensic Toxicology and Antidoping, University Hospital of Padova, Via Falloppio 50, I-35121 Padova, Italy.
Abstract:
A new method is described for the qualitative and quantitative analysis of midazolam, a short-acting 1,4-imidazole benzodiazepine, in human plasma. It involves a plasma deproteinization step, solid-phase microextraction (SPME) of midazolam using an 85-microm polyacrylate fiber, and its detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode, using pinazepam as internal standard. The assay is linear over a midazolam plasma range of 1.5-300 ng/mL, relative intra- and inter-assay standard deviations at 5 ng/mL are below 7%, and the limit of detection is 1 ng/mL. The method is simple, fast and sufficiently sensitive to be applied in clinical and forensic toxicology as well as for purposes of therapeutic drug monitoring.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023