Abstract:
The development of flexible polyurethane heart valves has been hindered by material degradation in vivo. Low modulus polyurethane leaflets are regarded as desirable to achieve good hydrodynamic function. However, low modulus materials may suffer high strain accumulation, hence poor durability. Higher modulus materials may improve durability, but may have poor hydrodynamic function. This study examines the hydrodynamic behaviour of biostable polyurethane valves, varying Young's modulus from 5 to 63.6 MPa and mean leaflet thickness from 48-238 microm. Parameters studied included mean pressure gradient, energy losses and regurgitation over 5 equivalent cardiac outputs (3.6, 4.9, 6.4, 8.0 and 9.61 min(-1)) At low cardiac output, modulus was not significantly correlated with any parameter of valve opening. At 9.61 min(-1), modulus significantly influenced mean pressure gradient (p = 0.033). Mean leaflet thickness significantly correlated with mean pressure gradient and energy losses during forward flow at all cardiac outputs (p<0.001). This study demonstrates that, over a wide range of moduli, valve hydrodynamic function is not affected significantly by the material modulus. Leaflet thickness is a highly significant factor. Higher modulus elastomers in a range up to 32.5 MPa may be useful in prosthetic heart valve leaflet manufacture, retaining good hydrodynamic function while potentially extending the lifetime of the valve.
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Typical Model Studies
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Hooke's Law
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...