The development and operational evaluation of a calibration gas generator for the analysis of volatile or ganic compounds (VOC) in air is described. Details of the construction, as well as of the evaluation of the apparatus are presented here. The performance of the test gas generator is validated both by on-line GC analysis of the calibration gas produced and by off-line analysis of adsorptive samples taken from the generated calibration gas. Both, active and passive sampling have been used, and the results demonstrate the excellent accuracy and precision of the generated test gas atmosphere: For the 11 investigated organic compounds (aromatic and halogenated compounds), the found values were in most cases within 5% of the target value with a reproducibility of better than 3% RSD (as determined by the analysis of the sampled adsorbent tubes). Custom made adsorbent tubes were used for active and passive sampling and in both cases were analysed by thermal-desorption GC. Particularly the combination of passive sampling and thermodesorption-GC analysis offers significant advantages over the commonly used active sampling on activated charcoal, followed by CS2 desorption in terms of avoidance of hazardous solvents, potential for automation and improved detection limits. Both sampling techniques are capable for monitoring VOCs at concentrations and under conditions relevant for workplace monitoring.
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...