We report observations of the first low-to-high ( L-H) confinement mode transitions in the National Spherical Torus Experiment. The H-mode energy confinement time increased over reference discharges transiently by 100-200%, as high as approximately 100 ms. This confinement time is approximately 2 times higher than predicted by a multimachine scaling. Thus the confinement time of spherical tori has been extended to a record high value, leading to an eventual revision of confinement scalings. Finally, the power threshold for H-mode access is >10x higher than predicted by an international scaling from conventional aspect-ratio tokamaks, which could lead to new understanding of H-mode transition dynamics.