Related Experiment Video
Updated: Oct 2, 2026

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Solid-phase microextraction method for the determination of atrazine and four organophosphorus pesticides in soil
A Bouaid1, L Ramos, M J Gonzalez
1Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Spain.
Abstract:
A simple and rapid solid-phase microextraction (SPME) based method is presented for the simultaneous determination of atrazine and four organophosphorus (i.e. parathion-methyl, chlorpyriphos, methidathion and carbophenothion) in soils. After optimisation of the different experimental variables affecting the SPME of the target compounds from aqueous solutions by using an experimental design, a consensus strategy was adopted which allowed the use of the SPME method developed for the simultaneous screening of all the analytes selected. The complete analytical procedure finally proposed consisted of a 15-min ultrasonic extraction of the target compounds from a 0.5-g soil sample with 5 ml of methanol and the dilution of this extract to up 10% methanol followed by the addition of NaCl to a final concentration of 10% (w/v). The analytes in this aqueous extract were preconcentrated for 30 min in the SPME fiber and subsequently desorbed by heating of the fiber at 260 degrees C for 5 min in the gas chromatograph injection port. Final determination was carried out with an electron-capture detector. The recoveries of the pesticides studied in soils ranged from 72 to 123%, except for atrazine, and the SDs were below 16%. The feasibility of the procedure finally proposed for the screening of the endogenous pesticides irrespective of the properties of the soil selected has been shown.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
