Related Experiment Video
Updated: Oct 2, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Spectral changes and 1 X N spectral switches in the diffraction of partially coherent light by an aperture
1Department of Physics, Huaqiao University, Quanzhou, Fujian, China. jixiong@hqu.edu.cn
Abstract:
The off-axis and on-axis spectra in the far zone of an aperture for the case in which a particular class of partially coherent light with a broad spectrum is diffracted by an aperture are studied. It is shown that the spectrum in the far zone is generally different from that at the aperture; i.e., the spectrum is split into two or more peaks. Moreover, the spectrum varies with the diffractive angle. For a fixed diffractive angle, the spectral shift, defined as the difference between the frequencies at which the observed spectrum and the spectrum at the aperture take their maximum, shows a gradual change with the change in the coherence at the aperture. However, as the coherence reaches some critical values, the spectral shift exhibits a rapid transition; i.e., spectral switch occurs. The coherence that causes the spectral switch to take place is different for different diffractive angles. Therefore we propose a new kind of 1 x N spectral switch, where N detectors (output ports) are placed at different diffractive angles in the far zone, and the spectral shifts at different detectors are measured. By adjusting the coherence of the aperture (input port) to the desired values, we obtain a rapid transition of the spectral shift in the desired output ports.
Related Concept Videos
Interference and Diffraction
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
The de Broglie Wavelength
Atomic Spectroscopy: Absorption, Emission, and Fluorescence

