Related Experiment Videos
The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography
Jianhua Wang1, Desmond Fonn, Trefford L Simpson
1Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada.
Purpose:
To determine if corneal epithelial thickness increases in association with corneal edema induced by wearing soft contact lenses during eye closure.
Design:
Experimental study.
Methods:
One eye (randomly selected) of twenty noncontact lens wearers (10 males and 10 females, age 35.6 +/- 9.6 years) was patched during 3 hours of soft contact lens (SCL) wear and the contralateral eye acted as a control. Corneal and epithelial thickness of both eyes was measured before and after SCL wear using optical coherence tomography (OCT).
Results:
Immediately after contact lens removal, total corneal thickness was increased significantly by 13.8 +/- 2.3% (mean +/- SD) compared with baseline (P <.0001, paired t test) and after 100 minutes was still 4.5 +/- 2.3% thicker than baseline (P <.0001, paired t test). The control eyes showed no change in total corneal thickness (P >.05, paired t test). Immediately after contact lens removal, corneal epithelial thickness was increased by 1.7 +/- 4.8%, but this change was not statistically significant (P >.05, paired t test). Following contact lens removal, epithelial thickness changed significantly (Repeated measure analysis of variance [Re-ANOVA]: F((7,133)) = 4.91, p(H-F) < 0.001) over the next 100 minutes with thinning recorded at 60, 80, and 100 minutes (P <.05, paired t test). There was no significant change over time in epithelial thickness of the control eyes (Re-ANOVA: F(4, 76) = 0.91, p(H-F) = 0.464).
Conclusion:
OCT demonstrated that corneal epithelial thickness does not increase in response to hypoxia from SCL wear and eye closure, in contrast to a significant increase in total corneal thickness.