Objective:
To focus on the reliability of ambulatory blood pressure monitoring and on its limitations in clinical practice, and to construct adequate strategies to improve ambulatory monitoring performance.
Methods:
The literature was reviewed, and personal data were used.
Discussion:
Since the beginning of non-invasive ambulatory blood pressure monitoring, it appeared that some subjects had a high proportion of outlying readings that were unlikely to be accurate. Although ambulatory blood pressure is more reproducible than clinic blood pressure, large day-to-day differences have also been reported in reproducibility studies for average 24 h blood pressure. It has been shown that, for day-to-day 24 h blood pressure differences greater than 4/3 mmHg, ambulatory blood pressure is poorly predictive of the degree of target organ damage. The variability of average 24 h blood pressure may arise from several causes, including true biological variability, a lack of standardization of activities and measurement errors. Artefactual readings can easily occur if patients are not properly instructed. Although editing procedures can eliminate outliers, it is often impossible to identify inaccurate readings included within the patient's trend. To optimize ambulatory blood pressure monitoring, health-care providers should be instructed adequately on how to perform this technique. Appropriate patient selection, a proper application of instrumentation and the checking of its performance, careful instructions to patients, the immediate evaluation of the patient's diary and 24 h tracing after completion of the recording should improve the results of ambulatory monitoring.
Conclusions:
A checklist of criteria that should be used for optimizing ambulatory monitoring in clinical practice should be proposed by the Consensus Conference on ambulatory blood pressure monitoring. To improve doctors' proficiency, strategies including educational protocols and training programmes should be implemented.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...