Related Experiment Video
Updated: Aug 2, 2026

A System to Create Stable Nanoparticle Aerosols from Nanopowders
Published on: July 26, 2016
The variability of delivered dose of aerosols with the same respirable concentration but different size distributions
N A Esmen1, D L Johnson, G M Agron
1Aerosols Research Laboratory, University of Oklahoma Health Sciences Centre, PO Box 26901, Oklahoma City 73190, USA. nurtan-esmen@ouhsc.edu
Abstract:
The influences of aerosol size distribution and breath tidal volume on respirable dose estimates were examined for mouth breathing using the ACGIH/ISO/CEN criterion for respirable-equivalent aerosols. Actual tissue doses predicted from a set of pulmonary empirical deposition equations, the Heyder-Rudolf equations, were compared with deposition assumed to occur under the penetration-based respirable dust sampling criterion. Deposition estimate errors ranged from approximately 1/10- to 10-fold, with aerosol mass median aerodynamic equivalent diameter and geometric standard deviation as well as tidal volume each showing a substantial influence under appropriate conditions. These findings demonstrate that reliance on respirable aerosol sampling data obtained with devices performing on a penetration-based sampling criterion may lead to erroneous dose-response relationships in exposure standard development as well as exposure misclassification errors during epidemiological studies. A more reliable dose estimate would be obtained using devices with collection efficiency performance closely matching the alveolar deposition prediction curves of Heyder and Rudolf. We believe that if it is not currently required, the development of a deposition-based aerosol sampling methodology will soon be required for the determination and quantification of inhaled aerosol-induced adverse health effects.
Related Concept Videos
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence
Dosage Regimen: Individualization
Dose Size and Dosing Frequency: Determination Methods