Related Experiment Video
Updated: Aug 17, 2026

The Bovine Lung in Biomedical Research: Visually Guided Bronchoscopy, Intrabronchial Inoculation and In Vivo Sampling Techniques
Published on: July 3, 2014
Role of transbronchial needle aspiration in patients receiving mechanical ventilation
Shekhar Ghamande1, Albert Rafanan, Raed Dweik
1Department of Pulmonary and Critical Care, Cleveland Clinic Foundation, OH 44195, USA.
Study Objective:
s: To evaluate the diagnostic accuracy and safety of transbronchial needle aspiration (TBNA) in patients receiving mechanical ventilation in the ICU.
Methods:
Retrospective review of all patients in the medical and surgical ICUs from February 1999 to July 2001 who underwent TBNA while receiving mechanical ventilation.
Results:
A total of eight histology (19 gauge) and eight cytology (22 gauge) TBNAs were performed on eight patients (four men and four women). TBNA yielded a definitive pathologic diagnosis in five of eight patients (62.5%). Diagnoses were posttransplantation lymphoproliferative disorder, large cell carcinoma, poorly differentiated non-small cell carcinoma, squamous cell carcinoma, and adenocarcinoma. Among patients with negative TBNA results (n = 3), two patients underwent mediastinoscopy. Results of mediastinoscopy were non-small cell carcinoma and inflamed tissue. TBNA led to management changes in five of these patients. Excluding one patient in whom a negative TBNA result could not be further confirmed, TBNA yielded a sensitivity of 83%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 50%. The overall accuracy of the procedure was 75%. There were no complications following any of the TBNAs.
Conclusions:
In this small group of patients, TBNA was safe and had a high diagnostic accuracy in selected patients receiving mechanical ventilation in the ICU.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques