Related Experiment Videos
An alternative linear stapling technique for performing Roux-en-Y anastomosis
Marcel Autran C Machado1, Paulo Herman, André L Montagnini
1Department of Abdominal Surgery, Cancer Hospital, São Paulo, Brazil.
American Journal of Surgery
|November 16, 2002
Summary
A modified gastrointestinal anastomosis technique uses fewer stapling devices, reducing costs without compromising results. This method is ideal for resource-limited hospitals.
Area of Science:
- Surgical Innovation
- Gastrointestinal Surgery
Background:
- Gastrointestinal anastomosis commonly uses stapling devices.
- Hospitals face stapling device shortages due to cost-saving measures.
Observation:
- A modified technique was developed to decrease the number of stapling devices required.
- This involves a single stapled procedure for jejunum section and side-to-side jejunoanastomosis.
Findings:
- The modified technique was employed for one year.
- No complications related to the stapled anastomosis were observed.
Implications:
- This approach can shorten Roux-en-Y anastomosis reconstruction time.
- It offers a cost-effective solution for hospitals with limited economic resources.