Related Experiment Videos
Relationship of dentin shear bond strengths to different laboratory test designs
Sabine H Dickens1, Michael F Milos
1Polymer Program, Paffenbarger Research Center, American Dental Association Health Foundation, National Institute of Standards and Technology, Gaithersburg, MD 20899-8546, USA. sabine.dickens@nist.gov
Purpose:
To compare 6 shear bond test procedures using 2 primers by evaluating differences in strength and fracture surfaces.
Materials And Methods:
Part I - a 2(3)-factorial design evaluated the effects of (1) 2 primer systems, (2) the dentin moisture level, and (3) the application technique defining the bond area. The outcome of Part I then led to choosing for Part II one primer system, applying the primer the entire surface with moist dentin as the substrate while comparing 6 shear test designs: (1) knife-edged chisel-on-iris; (2) similar to 1 with support added to the tooth; (3) chisel on composite plug; (4) similar to 3 with support added; (5) wire loop on composite plug; (6) modified Watanabe assembly.
Results:
In Part I mean shear bond strengths (SBS) ranged from 14-36 MPa. SBS was highest for either primer when it was applied to moist dentin over the entire dentin surface. Each of the factors, moisture level, primer system and application technique significantly affected SBS (3-way ANOVA, P<0.05). The effects from each primer system on SBS depended on the surface moisture or the application technique, indicating significant interactions. In Part II, mean SBS ranged from 18-32 MPa with Groups 1 and 2 having significantly higher bond strengths than the others (P<0.05).