Related Experiment Video
Updated: Sep 26, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Stereoselective determination of pyridoglutethimide enantiomers in serum with a chiral cellulose-based
1Department of Analytical Chemistry, Faculty of Pharmacy, University of Mansoura, Mansoura 35516, Egypt. mhefnawy@mans.edu.eg
Abstract:
A sensitive method for the separation and determination of R(+)- and S(-) enantiomers of pyridoglutehimide in serum by high performance liquid chromatography (HPLC) with UV detection was developed. The assay involves the use of a solid-phase extraction for serum sample clean-up prior to HPLC analysis using a C18 Bond-Elute column. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OD-R, 250 x 4.6 mm I.D.) under isocratic conditions using a mobile phase of 25:75 v/v acetonitrile-0.3 M aqueous sodium perchlorate (pH 6.2 adjusted with perchloric acid) at a flow rate of 0.8 ml/min. Recoveries for R(+)- and S(-)-pyridoglutethimide enantiomers were in the range 86-91% at 300-900 ng/ml level. Intra-day and inter-day precision calculated as %R.S.D. were in the ranges of 2.9-3.9 and 1.5-4.7% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percentage error were in the ranges of 1.9-3.3 and 1.5-3.9% for both enantiomers, respectively. Linear calibration curves in the concentration ranges of 100-1500 ng/ml for each enantiomer show correlation coefficient (r) of more than 0.9995. The limit of quantification (LOQ) of each enantiomer was 100 ng/ml using 1 ml of serum. The detection limit (LOD) for each enantiomer in serum using a UV detection set at 257 nm was 50 ng/ml (S/N = 2).
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
Types Of Column Chromatography
Gel Filtration Chromatography
When the...