Related Experiment Videos
Acute angle-closure glaucoma after successful embolization of traumatic carotid-cavernous sinus fistula--case report
Masaki Komiyama1, Toshie Morikawa, Yasuhiro Matsusaka
1Department of Neurosurgery, Osaka City General Hospital, Osaka, Japan. komiyama@japan-mail.com
Neurologia Medico-Chirurgica
|April 18, 2003
Abstract:
A 69-year-old woman developed acute angle-closure glaucoma 2 weeks after successful transvenous coil embolization of a traumatic carotid-cavernous sinus fistula. The angle-closure glaucoma was precipitated by oculomotor palsy caused by transvenous coil packing of the cavernous sinus. Emergency iridotomy resulted in normalization of the intraocular pressure and restoration of vision. Acute angle-closure glaucoma may develop in association with an oculomotor palsy caused by any etiology, including neurointervention.