2D-RF-pulse-encoded curved-slice imaging.

Peter Börnert1

  • 1Department Technical Systems, Philips Research, Röntgenstrasse 24-26, 22335 Hamburg, Germany. Peter.Boernert@Philips.com

Magma (New York, N.Y.)
|July 10, 2003
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Time-Conditioned Zero-Shot Self-Supervised Reconstruction for Accelerated 3D Ultra-Low-Field MRI.

Magnetic resonance in medicine·2026
Same author

Navigator-free multi-shot diffusion MRI via non-local low-rank reconstruction.

Magnetic resonance in medicine·2025
Same author

Referenceless 4D flow MRI using radial balanced SSFP at 0.6 T.

Magnetic resonance in medicine·2025
Same author

Rapid quantitative MRI at 46 mT: Accelerated T<sub>1</sub> and T<sub>2</sub> mapping with low-rank reconstructions.

Magnetic resonance in medicine·2025
Same author

Denoising low-field MR images with a deep learning algorithm based on simulated data from easily accessible open-source software.

Journal of magnetic resonance (San Diego, Calif. : 1997)·2024
Same author

Chemical shift-encoded multishot EPI for navigator-free prostate DWI.

Magnetic resonance in medicine·2024
Same journal

Influence of gadolinium-based contrast agent (GBCA) on the diffusion weightings of breast lesions: an intra-patient analysis.

Magma (New York, N.Y.)·2026
Same journal

Evaluation of the diffusion time dependence of the IVIM effect based on realistic capillary flow simulations in mouse brain.

Magma (New York, N.Y.)·2026
Same journal

An evaluation of brain volume and cortical thickness measurement at 0.55 T.

Magma (New York, N.Y.)·2026
Same journal

Net zero emission MR imaging using a permanent 0.4 T magnet.

Magma (New York, N.Y.)·2026
Same journal

Special issue on "deuterium metabolic imaging".

Magma (New York, N.Y.)·2026
Same journal

Black-blood dynamic contrast-enhanced MRI of abdominal aortic aneurysms.

Magma (New York, N.Y.)·2026
See all related articles

This study introduces a novel magnetic resonance imaging (MRI) method for directly visualizing curved anatomical structures. The new curved-slice imaging technique utilizes 2D radiofrequency (RF) pulses and frequency encoding for enhanced spatial resolution.

Area of Science:

  • Medical Imaging
  • Magnetic Resonance Imaging (MRI)
  • Biomedical Engineering

Background:

  • Conventional MRI techniques often struggle to directly image complex curved anatomical structures.
  • Acquiring images of curved anatomy typically requires multiple conventional slices, increasing scan time and complexity.
  • There is a need for advanced MRI methods capable of high-resolution imaging of non-planar anatomical regions.

Purpose of the Study:

  • To develop and demonstrate a novel curved-slice magnetic resonance imaging (MRI) approach.
  • To achieve direct, high-resolution imaging of arbitrarily shaped curved anatomical structures.
  • To validate the feasibility of the proposed curved-slice imaging technique using phantom and in vivo experiments.

Main Methods:

  • Implementation of a novel imaging sequence employing a set of 2D radiofrequency (RF) pulses to excite magnetization within a curved slice profile.

Related Experiment Videos

  • Utilizing specially designed RF pulses and an encoding scheme to achieve spatial resolution along the curved-slice direction.
  • Employing conventional frequency encoding for spatial resolution in the remaining direction.
  • Main Results:

    • Demonstrated the basic feasibility of the curved-slice imaging approach through phantom studies.
    • Validated the technique with in vivo experiments, showcasing its potential for imaging curved anatomy.
    • Identified the current limitations of the developed curved-slice MRI method.

    Conclusions:

    • The novel curved-slice MRI technique enables direct imaging of curved anatomical structures.
    • The method combines 2D-RF pulses with conventional frequency encoding for spatial resolution.
    • Further development is needed to overcome identified limitations, but the approach shows significant promise for specialized MRI applications.