Single breath-hold diffusion-weighted imaging of the abdomen
Lawrence C Chow1, Roland Bammer, Michael E Moseley
1Department of Radiology, Stanford University Medical Center, Stanford, California 94305, USA. ichow@stanford.edu
Purpose:
To generate high quality diffusion-weighted images (DWI) and corresponding isotropic ADC maps of the abdomen with full organ (kidneys) coverage in a single breath-hold.
Materials And Methods:
DWI was performed in 12 healthy subjects with an asymmetric, spin-echo, single-shot EPI readout on a system with high performance gradients (40 mT/minute). The isotropic diffusion coefficient
Results:
This technique yielded images of quality and resolution which compares favorably to that of prior work. SNR ranged from 27.0 in liver to 44.1 in kidneys for the diffusion-weighted images, and from 19.6 in liver to 39.0 in kidneys in reference images. ADCs obtained in the renal medulla, renal cortex, liver, spleen, and pancreas were (2091 +/- 55) x 10(-6), (2580 +/- 53) x 10(-6), (1697 +/- 52) x 10(-6), (1047 +/- 82) x 10(-6), and (2605 +/- 168) x 10(-6) mm(2)/second, respectively (mean +/- SE). Apparent diffusion coefficient (ADC) in the renal medulla and cortex were significantly different by paired t-test (P = 4.22 x 10(-10)). Renal medulla and cortex yielded anisotropy indices (AI) of 0.129 and 0.067, respectively.
Conclusions:
1) Single-shot SE EPI DWI in the abdomen with this technique provides high quality images and