Related Experiment Video
Updated: Aug 19, 2026

Development of an In Vitro Ocular Platform to Test Contact Lenses
Published on: April 6, 2016
Ocular surface residence times of artificial tear solutions
G R Snibson1, J L Greaves, N D Soper
1Department of Ophthalmology, University of Oxford, England.
Abstract:
Solutions of hydroxypropylmethylcellulose (HPMC) and polyvinyl alcohol (PVA) are widely used as artificial tears. However, their usefulness is limited by the short duration of their effect. Dilute sodium hyaluronate (SH) solutions exhibit non-Newtonian rheology with high viscosities at low shear rates, which would be expected to enhance their ocular surface residence time. Using quantitative gamma scintigraphy, estimates of the ocular surface residence times of 0.3% HPMC, 1.4% PVA, and 0.2% SH were made in six patients with keratoconjunctivitis sicca. The sodium hyaluronate solution had a mean half-life on the ocular surface of 321 s, significantly longer than hydroxypropylmethylcellulose (44 s; p = 0.012) and polyvinyl alcohol (39 s; p = 0.013).
Related Concept Videos
Ophthalmic Drug Delivery Systems
Microbiome of the Eye