Related Experiment Video
Updated: Aug 30, 2026

Simultaneous Measurements of Intracellular Calcium and Membrane Potential in Freshly Isolated and Intact Mouse Cerebral Endothelium
Published on: January 20, 2019
Flow-injection biamperometric direct determination of calcium dobesilate in irreversible couple system
1Institute of Analytical Science, Northwest University, Xi'an 710069, China. songjunf@nwu.edu.cn
Abstract:
A flow-injection biamperometric method for direct determination of calcium dobesilate had been proposed based on biamperometric detection for irreversible couple. The detection was realized by coupling the oxidation of dobesilate at one platinum wire electrode with the reduction of MnO(4)(-) at another one with the applied potential difference of 0 V between two platinum wire electrodes. Dobesilate was determined in the range of 4.0 x 10(-6) to 1.0 x 10(-4) M with the detection limit of 8.0 x 10(-7) M (S/N=3). The relative standard derivation of 1.7% was obtained for 24 successive determinations of 4.0 x 10(-5) M dobesilate. The proposed method had been shown to be sensitive, simple and rapid.