General-purpose infusion pumps. Evaluating the B. Braun Outlook Safety Infusion System
Abstract:
General-purpose infusion pumps deliver liquid medications and intravenous (i.v.) fluids to patients through i.v. or epidural routes at specified flows. They are most often used when greater accuracy or higher flows are needed than can be provided by a manually adjusted gravity administration set. In this Evaluation (which updates our October 2002 study), we present our findings for two newly evaluated pumps: the B. Braun Outlook 100 and Outlook 200. The Outlook 200 is the first general-purpose infusion pump to offer a new type of safety feature: an automated programming system. This system scans bar-coded labels on i.v. fluid containers and on patient (and sometimes clinician) identification and automatically programs this information into the pump. Unfortunately, the 200's system has not yet been successfully implemented in a clinical setting.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...