Related Experiment Video
Updated: Jul 27, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Distribution dynamics of perfluorocarbon delivery to the lungs: an intact rabbit model
J L Bull1, S Tredici, E Komori
1Department of Biomedical Engineering, The University of Michigan, Ann Arbor, MI 48109, USA. joebull@umich.edu
Abstract:
Motivated by the goal of understanding how to most homogeneously fill the lungs with perfluorocarbon for liquid ventilation, we investigate the transport of liquid instilled into the lungs using an intact rabbit model. Perfluorocarbon is instilled into the trachea of the ventilated animal. Radiographic images of the perfluorocarbon distribution are obtained at a rate of 30 frames/s during the filling process. Image analysis is used to quantify the liquid distribution (center of mass, spatial standard deviation, skewness, kurtosis, and indicators of homogeneity) as time progresses. We compare the distribution dynamics in supine animals to those in upright animals for three constant infusion rates of perfluorocarbon: 15, 40, and 60 ml/min. It is found that formation of liquid plugs in large airways, which is affected by posture and infusion rate, can result in a more homogeneous liquid distribution than gravity drainage alone. The supine posture resulted in more homogeneous filling of the lungs than did upright posture, in which the lungs tend to fill in the inferior regions first. Faster instillation of perfluorocarbon results in liquid plugs forming in large airways and, consequently, more uniform distribution of perfluorocarbon than slower instillation rates in the upright animals.