Electrochemical determination of oxytetracycline in veterinary drugs
Marzanna Kurzawa1, Agnieszka Kowalczyk-Marzec
1Faculty of Chemistry, Nicolaus Copernicus University, 87-100, Toruń, ul. Gagarina 7, Poland. jmk@cc.uni.torun.pl
Abstract:
Conductometric, potentiometric and cyclic voltammetric (CV) titration methods are proposed for determination of oxytetracycline (OTC), commonly used in veterinary. The electrochemical titration of OTC hydrochloride with NH(4)Mo(7)O(24), NaVO(3), NaOH, AgNO(3) and FeCl(3) as titrants are reported. The proposed methods were found to be highly precise, having a relative standard deviation (R.S.D.) below 1.0%. Proposed electrochemical titrations were successfully applied to the assay of commercial preparations: Tetrox, Tetramutin OT and Neox, containing the above-mentioned antibiotics. The validity of the methods was tested by the recovery studies of standard addition to pharmaceuticals and results were found to be satisfactory.
More Related Videos
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...