Related Experiment Video
Updated: Aug 29, 2026

An Automated System for Sound Localization Testing in Hearing-Impaired Listeners
Published on: March 13, 2026
[Analysis of the sound-insulation effects of control rooms in workshops with noise]
1Institute of Occupational Diseases, Nanping Fujian 353000, China.
Objective:
To study the main factors affecting sound-insulation effects of control rooms in workshops with noise, so as to improve the protection.
Methods:
The sound-insulation effects of 467 control rooms were determined, and different building materials, structures of door and window, airtight states etc. were analyzed.
Results:
The affecting factors contributed to the sound-insulation effects (Eta(2)) were in the order: airtight states (0.168), building materials (0.080), structures of window and door (0.030, 0.029), sound pressure levels and frequency spectrum's characteristics (0.008, 0.006). Under airtight state, the sound-insulation effects of different building materials of the rooms were as follows: double bricks [(19.6 +/- 3.5) dB(A)]; single brick [(15.4 +/- 3.4) dB(A)]; plank [(13.1 +/- 1.6) dB(A)] or aluminum alloy plate with glass [(13.4 +/- 2.5) dB(A)] (P < 0.01). Of 4 group rooms, with the same structure of doors but double or single bricks of windows. 3 groups with dormant window had higher sound-insulation effects [(15.9 +/- 2.8), (18.7 +/- 3.6), (19.3 +/- 2.5) dB(A)] than those with casement window [(14.1 +/- 2.4), (14.9 +/- 2.3), (16.5 +/- 2.4) dB(A)] (P < 0.01 or P < 0.05); 2 groups with dehydrated window [(18.7 +/- 3.3), (22.6 +/- 3.8) dB(A)] higher than those with dormant window [(15.9 +/- 2.8), (19.9 +/- 3.0) dB(A)] (P < 0.05). Of 6 group rooms, with the same structure of windows but double or single bricks of doors, only in 1 group with double-layer door had higher sound-insulation effect [(18.7 +/- 3.6) dB(A)] than that with single-layer door [(15.9 +/- 2.8) dB(A)] (P < 0.01).
Conclusion:
The control room should be designed rationally, kept airtight, according to the sound pressure levels and the condition of the workshop.
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Soundness of Cement