Related Experiment Video
Updated: Aug 29, 2026

Using a Real-Time Locating System to Measure Walking Activity Associated with Wandering Behaviors Among Institutionalized Older Adults
Published on: February 8, 2019
Pedometer accuracy in nursing home and community-dwelling older adults
Elizabeth V Cyarto1, Anita M Myers, Catrine Tudor-Locke
1Department of Health Studies and Gerontology, University of Waterloo, Waterloo, Ontario, Canada.
Purpose:
The accuracy of pedometers has not been thoroughly tested with older adult populations. The purpose of the present study was to examine the effects of walking speed and gait disorders on the accuracy of Yamax pedometers with nursing home residents (NH) relative to older adults living in the community.
Methods:
Pedometer accuracy was evaluated against observed steps taken during a self-paced walking test (slow, normal, and fast speeds) in 26 NH residents and 28 seniors' recreation center members (SC). Devices were attached to clothing at the waist. Walking speed was ascertained from the timed walk and a gait assessment was conducted. Percent error was calculated as ([pedometer steps - observed steps]/observed steps) x 100.
Results:
The walking speeds of both samples increased across self-selected paces (P < 0.0001). The community-dwelling older adults walked significantly faster (P < 0.0001) in all trials and had significantly higher (P < 0.0001) gait assessment scores (indicating fewer gait problems). Gait scores were positively associated with walking speed and pedometer percent error. Pedometers significantly underestimated NH residents' observed steps taken by 74% (slow), 55% (normal), and 46% (fast) paces (P < 0.0001). In the SC sample, the instruments failed to detect 25%, 13%, and 7% of actual steps taken, respectively (P < 0.0001). The magnitude of the error was greater for NH versus SC older adults (P < 0.0001) across all trials.
Conclusions:
Slow walking speed and gait disorders hamper the utility of pedometers for physical activity measurement in frail seniors, such as NH residents, when worn at the usual attachment site. Pedometers, however, can be confidently used with ostensibly healthy older adult populations for both assessment and motivation purposes.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.