Related Experiment Video
Updated: Jul 28, 2026

Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
Single photon emission computed tomography using 201Tl chloride in pulmonary nodules: comparison with 67Ga citrate
K Itoh1, H Takekawa, E Tsukamoto
1Department of Nuclear Medicine, Hokkaido University School of Medicine, Sapporo, Japan.
Abstract:
A single photon emission computed tomography (SPECT) with 201Tl chloride (Tl-201) was carried out prospectively in 50 patients with pulmonary nodules and its diagnostic value was compared with those of 67Ga citrate (Ga-67) and 99mTc-labeled hexamethylpropyleneamine-oxime (Tc-99m-HMPAO). Tl-201 SPECT provided 88% (early)-91% (delayed) sensitivity, 85% (early and delayed) specificity and 87% (early)-89% (delayed) accuracy. The sensitivity of the Tl-201 planar image was 56 (early)-62% (delayed), which was significantly lower than that of SPECT. Delayed SPECT images at 2 hour postinjection were more preferable to disclose the malignant pulmonary nodule than early SPECT images at 15 minutes postinjection. The application of SPECT with Ga-67 failed to improve the sensitivity of planar imaging for malignant pulmonary nodules. Tc-99m-HMPAO was concentrated in 62% of 13 patients with malignant pulmonary nodules, which was slightly higher than Ga-67 in 54% of 28 patients. In an analysis of the histologic types of lung cancer, the sensitivity of Tl-201 was not significantly different in all types. On the other hand, Ga-67 was positive only in 25% of 12 patients with adenocarcinoma. A combination of SPECT and Tl-201 is the best choice among routine scintigraphic techniques for depicting malignant pulmonary nodules. The Tl-201 SPECT image may play a complementary role in the characterization of pulmonary nodules which are revealed on a plain radiograph and computed tomography.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

