Trilinear chemometric analysis of two-dimensional comprehensive gas chromatography-time-of-flight mass spectrometry data
Related Experiment Video
Updated: Aug 26, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Amanda E Sinha1, Carlos G Fraga, Bryan J Prazen
1Department of Chemistry, Centerfor Process Analytical Chemistry, Box 351700, University of Washington, Seattle, WA 98195-1700, USA.
Abstract:
Two-dimensional comprehensive gas chromatography (GC x GC) is a powerful instrumental tool in its own right that can be used to analyze complex mixtures, generating selective data that is applicable to multivariate quantitative analysis and pattern recognition. It has been recently demonstrated that by coupling GC x GC to time-of-flight mass spectrometry (TOFMS), a highly selective technique is produced. One separation on a GC x GC/TOFMS provides retention times on two chromatographic columns and a complete mass spectrum for each component within the mixture. In this manuscript, we demonstrate how the selectivity of GC x GC/TOFMS combined with trilinear chemometric techniques such as trilinear decomposition (TLD) and parallel factor analysis (PARAFAC) results in a powerful analytical methodology. Using TLD and PARAFAC, partially resolved components in complex mixtures can be deconvoluted and identified using only one data set without requiring either signal shape assumptions or fully selective mass signals. Specifically, a region of overlapped peaks in a complex environmental sample was mathematically resolved with TLD and PARAFAC to demonstrate the utility of these techniques as applied to GC x GC/TOFMS data of a complex mixture. For this data, it was determined that PARAFAC initiated by TLD performed a better deconvolution than TLD alone. After deconvolution, mass spectral profiles were then matched to library spectra for identification. A standard addition analysis was performed on one of the deconvoluted analytes to demonstrate the utility of TLD-initiated PARAFAC for quantification without the need for accurate retention time alignment between sample and standard data sets.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Tandem Mass Spectrometry
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Analyzers: Common Types