Related Experiment Videos
Biocompatibility of synthetic oxygen carriers and fluorosurfactants
H Northoff1, L Haidmann, G Hänsch
1DRK-Blutspendezentrale Ulm, FRG.
Infusionstherapie Und Transfusionsmedizin
|June 1, 1992
Abstract:
A system for testing the biocompatibility of synthetic oxygen carriers is described including tests of hemolysis, complement activation and proliferation of cell lines or lymphocytes. Of 17 surfactants tested in this system, 6 were compatible in all tests while the other compounds showed individually differing patterns of incompatibility. We conclude that, in order to conduct a meaningful screening, a series of different assays has to be applied. In addition to our system, further assays, covering cytokine induction and phagocytosis should be attempted.