Experimental determination of calibration settings for plastic syringes containing solutions of 90Y using commercial
B E Zimmerman1, J T Cessna, M A Millican
1Ionizing Radiation Division, National Institute of Standards and Technology, Department of Physics Laboratory, 100 Bureau Drive, Gaithersburg, MD 20899-8462, USA. bez@nist.gov
Abstract:
Calibration factors for several makes (Capintec, AtomLab, and PTW) and models of commercially available re-entrant ionization chambers ("dose calibrators") were determined for solutions of 90Y using 10 ml plastic syringes that are used in the administration of the recently approved radioimmunotherapy drug Zevalin. Effects of filling volume on chamber response were studied for the anticipated prescription volume range of 3-9 ml in those syringes. A series of syringes were prepared over that range with accurately known volumes using a "standard" solution containing 90YCl3 in 1 moll(-1) HCl and approximately 50 microg of nonradioactive YCl3 per gram of solution. The respective calibration factors for the Capintec and AtomLab chambers required to give the correct activity reading were found to be "55+/-2 x 10" and 393+/-6, where the uncertainties are expanded (k = 2) uncertainties. The results indicated no significant effect of filling volume on the calibration setting to within the uncertainty on the activity measurement for all but the PTW chamber. In that case, a variation of about 5% was observed over the filling range. A direct comparison was also made between the actual 90Y Zevalin drug and the "standard" solution, with no differences in determined calibration settings observed within the uncertainties on the activity calibration.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...