Related Experiment Videos
Three-dimensional finite element stress analysis of a cantilever fixed partial denture
H A Awadalla1, M Azarbal, Y H Ismail
1Department of Prosthodontics, University of Pittsburgh, School of Dental Medicine, Pa.
The Journal of Prosthetic Dentistry
|August 1, 1992
Abstract:
A three-dimensional mathematical model was generated, representing a three-unit cantilever fixed partial denture and its supporting mandibular structures. First and second premolars were used as abutments with one posterior cantilever pontic. A 5 lb vertical load was applied to the pontic. Vertical and horizontal stresses were analyzed by means of a three-dimensional finite element stress analysis technique. The results showed that a cantilever pontic creates considerable compressive stress on the abutment nearest to the pontic and produces tensile stress on the abutment farthest from the pontic.