Related Experiment Video
Updated: Aug 6, 2026

Characterization of Electrode Materials for Lithium Ion and Sodium Ion Batteries Using Synchrotron Radiation Techniques
Published on: November 11, 2013
Dilatometric and mass spectrometric investigations on lithium ion battery anode materials
M R Wagner1, P R Raimann, A Trifonova
1Institute for Chemical Technology of Inorganic Materials, Graz University of Technology, Stremayrgasse 16, 8010, Graz, Austria. robby@sbox.tugraz.at
Abstract:
Lithium ion batteries operate beyond the thermodynamic stability of the aprotic organic electrolyte used. In 1 M LiClO(4) propylene carbonate electrolyte, with and without the addition of ethylene sulfite as a film forming electrolyte additive, we have used in situ electrochemical dilatometry and on-line electrochemical mass spectrometry to study the volume expansion/contraction of graphitic anodes and the formation of propylene gas, which both can occur during the graphite anode reduction (charge) process. The combination of both methods allows us to get insights into the respective electrolyte reduction mechanisms. The results indicate that the major failure mechanisms of graphitic anodes in pure PC electrolyte can be attributed to the intercalation of solvated lithium ions and the formation of propylene gas, which causes the graphite particles to exfoliate and crack.