Related Experiment Video
Updated: Aug 14, 2026

08:58
High-Throughput Measurement and Classification of Organic P in Environmental Samples
Published on: June 8, 2011
Applying the Yb3+ ion as a simple and sensitive probe to detect phosphate-containing derivatives in aqueous solution
Caixia Yin1, Fei Gao, Fangjun Huo
1Institute of Molecular Science, Chemical Biology and Molecular Engineering Laboratory of Education Ministry, Shanxi University, Taiyuan 030006, China. yangpin@sxu.edu.cn
Abstract:
A simple and sensitive detection method for HPO(4)(2-) and phosphate-containing derivatives in aqueous solution with a new ensemble which is prepared by mixing ytterbium chloride and pyrocatechol violet in a 2:1 molar ratio in 10 mM HEPES buffer at pH 7.0.
Related Concept Videos
Labeling DNA Probes
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Potentiometry: Membrane Electrodes
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Photoluminescence: Applications
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Phosphate Buffer
The phosphate buffer system is a critical biological mechanism for maintaining pH stability in the body. This system operates primarily through two components: sodium dihydrogen phosphate (NaH2PO4), which acts as a weak acid, and sodium hydrogen phosphate (Na2HPO4), which serves as a weak base.
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...

