Related Experiment Video
Updated: Aug 23, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Superimposition of a mechanical valve on an impacted aortic bioprosthesis
H Raffa1, K Al-Ibrahim, A A Sorefan
1Department of Cardiac Surgery, King Fahd Heart Center, Jeddah, Kingdom of Saudi Arabia.
Abstract:
During reoperation for replacement of a regurgitant aortic bioprosthesis (a 23-mm bovine pericardial valve), it was judged that total removal of the valve would be difficult, and hazardous to the patient. Therefore, its leaflets were excised and its sewing ring left in situ. A 21-mm Carbomedics bileaflet mechanical valve was sutured to the bioprosthetic sewing ring and implanted in the orifice of the bioprosthesis, resulting in excellent hemodynamic performance. We report this new technique to illustrate its feasibility, safety, and efficiency, as an alternative to complete removal of defective prostheses in the aortic position.
Related Concept Videos
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm III: Interprofessional Care
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management