Related Experiment Video
Updated: Oct 23, 2026

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
Determination of selenium by inductively coupled plasma mass spectrometry utilizing a new hydride generation sample
W T Buckley1, J J Budac, D V Godfrey
1Agriculture Canada Research Station, Agassiz, British Columbia.
Abstract:
An inductively coupled plasma mass spectrometer with a newly designed continuous flow hydride generator was used for the determination of Se in biological materials. The design of the hydride generator was important in minimizing interference from HCl and in maximizing analytical sensitivity. Two sample preparation procedures incorporating either 3.8 or 7.2 M HCl in the final sample solutions were compared. Interference from Cu was eliminated by the addition of 0.2 M NaI to the sodium borohydride solution (3.8 M method) or by maintaining a high concentration of HCl in the sample solution (7.2 M method). The 3.8 M method had the advantage of minimizing exposure of expensive equipment to corrosive HCl fumes, whereas the 7.2 M method did not contaminate equipment with I and had no measurable sample-to-sample cross-contamination. In practice, cross-contamination from sample to sample in both methods was negligible during analysis. An important factor in minimizing cross-contamination from sample to sample was the elimination of the air bubble normally entrained between samples. Determination of isotopic tracer enrichment was linear from 0 to 320% enrichment, which provided a broad range for isotope dilution analysis. A detection limit of 6.4 pg of Se was observed under optimum conditions, whereas a detection limit of 1.3 ng of Se was found for routine analysis of 1-g samples of plant material. Selenium was accurately determined by isotope dilution analysis in a variety of biological reference materials.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
08:46Dose Uptake of Platinum- and Ruthenium-based Compound Exposure in Zebrafish by Inductively Coupled Plasma Mass Spectrometry with Broader Applications
Published on: April 21, 2022
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab