Related Experiment Video
Updated: Aug 11, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
High-frequency oscillatory ventilation and an interventional lung assist device to treat hypoxaemia and hypercapnia
1Department of Anaesthesiology, Johannes Gutenberg-University, Mainz, Germany. david@mail.uni-mainz.de
Abstract:
A male patient accidentally aspirated paraffin oil when performing as a fire-eater. Severe acute respiratory distress syndrome (Pa(o(2))/Fi(o(2)) ratio 10.7 kPa) developed within 24 h. Conventional pressure-controlled ventilation (PCV) with high airway pressures and low tidal volumes failed to improve oxygenation. Hypercapnia (Pa(co(2)) 12 kPa) with severe acidosis (pH<7.20) ensued. Treatment with high-frequency oscillatory ventilation (HFOV) and a higher adjusted airway pressure (35 cm H(2)O) improved the Pa(o(2))/Fi(o(2)) ratio within 1 h from 10.7 to 22.9 kPa, but the hypercapnia and acidosis continued. Stepwise reduction of the mean airway pressure (26 cm H(2)O), and oscillating frequencies (3.5 Hz), as well as increasing the oscillating amplitudes (95 cm H(2)O) resulted in an unchanged Pa(co(2)), but oxygenation worsened. The new pumpless extracorporeal interventional lung assist device (ILA, NovaLung, Hechingen, Germany) was therefore used for carbon dioxide elimination to enable a less aggressive ventilation strategy. Pa(co(2)) normalized after initiation of ILA. HFOV with a mean airway pressure of 32 cm H(2)O was maintained, but with a higher oscillatory frequency (9 Hz) and very low oscillatory amplitude (25 cm H(2)O). After 6 days, the patient was transferred to a conventional ventilator, and ILA was discontinued after 13 days without complications.
More Related Videos
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)