The Use of Gas Chromatography to Analyze Compositional Changes of Fatty Acids in Rat Liver Tissue during Pregnancy
Published on: March 13, 2014
Comprehensive two-dimensional gas chromatography in the analysis of dietary fatty acids
Tuulia Hyötyläinen1, Minna Kallio, Mari Lehtonen
1Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, Finland. Tuulia.hyotylainen@helsinki.fi
Abstract:
Comprehensive two-dimensional gas chromatography utilising a semi-rotating cryogenic modulator was applied to the analysis of dietary milk derived fatty acids. Four column combinations were tested: two polar-nonpolar and two different nonpolarpolar column combinations. Best results were obtained with a nonpolar-polar column set, with narrow-bore (50 microm ID) Carbowax column as the second column. The GC x GC method clearly improved the separation efficiency of the fatty acids in comparison with one-dimensional GC analysis and proved to be suitable for the quantification of the analytes. The relative standard deviations (RSD) of the retention times in the first and second dimensions were on average 0.06% and 4.9%, respectively. The relative RSD for peak volumes was on average 2.9%.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...