Peripheral arterial tonometry, oximetry and actigraphy for ambulatory recording of sleep apnea
Related Experiment Video
Updated: Aug 22, 2026

Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
Thomas Penzel1, Karl Kesper, Iris Pinnow
1Division for Pulmonary Diseases, Department of Internal Medicine, Hospital of Philipps-University, Baldingerstr. 1, D-35033 Marburg, Germany. penzel@mailer.uni-marburg.de
Abstract:
Autonomous nervous functions change with sleep stages and show characteristic changes associated with sleep disorders. Therefore, continuous monitoring of autonomous nervous functions during sleep can be used for diagnostic purposes. Recently, the peripheral arterial tonometry (PAT) has been introduced to determine peripheral arterial vascular tone on the finger being determined by sympathetic activity. We investigate a new ambulatory recording system which uses PAT, oximetry and actigraphy (Watch-PAT) in order to detect sleep apnea and arousal. The Watch-PAT is battery operated and attached to the wrist and has two finger sensors. Twenty-one patients with suspected sleep apnea were recorded with cardiorespiratory polysomnography and the new system in parallel. Seventeen recordings could be evaluated. The correlation for the apnea/hypopnea index derived from the sleep laboratory and the respiratory disturbance index derived from the Watch-PAT was r = 0.89 (p < 0.01) and between arousals and the respiratory disturbance index was r = 0.77 (p < 0.01). The correlation for the total sleep time compared between the two systems was r = 0.15 (n.s.). The Watch-PAT detects apneas and hypopneas with a reasonable reliability and it is very sensitive to arousals. The number of Watch-PAT events lies between the sum of apneas plus hypopneas and arousals. Arousals are not unique to apnea events and therefore the specifity of the Watch-PAT is limited. In conclusion, the Watch-PAT is well suited to perform therapy control studies in patients suffering from sleep apnea and being treated.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Sleep Apnea
The condition is more prevalent among...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...