Related Experiment Video
Updated: Aug 10, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
An advanced double column-switching technique (LC-LC) for liquid chromatography/electrospray ionisation tandem mass
Hannes Egle1, Rainer Trittler, Klaus Kümmerer
1Institute of Environmental Medicine and Hospital Epidemiology, University Hospital Freiburg, Hugstetter Str. 55, D-79106 Freiburg i. Br., Germany.
Abstract:
Caspofungin (MK-0991; L-743,872) is the first representative of a new important class of antifungal agents, the glucan synthesis inhibitors. To the authors' best knowledge, to date only one high-performance liquid chromatography (HPLC) method has been published for the determination of caspofungin in serum. Severe difficulties with sorption were described. We developed a new method which addresses these difficulties using an advanced column-switching technique for fully automated analysis of caspofungin in serum without any pre-treatment. Extraction was performed automatically inline, using a diol column, followed by chromatography on a CN column. Detection was performed by electrospray ionisation tandem mass spectrometry (ESI-MS/MS) with isolation and fragmentation in the positive ion mode. Total analysis time was 30 min. Detection of caspofungin was achieved by retention time, isolation and fragmentation of the double positively charged caspofungin ion. This LC/MS assay was validated for between-run accuracy (max. 110%) and precision (max. CV 16.1%). The lower limit of quantification was 0.2 microg/mL. The analytical method with fully automated inline extraction of caspofungin described here removes the need for difficult and time-consuming sample pre-treatment. Sorption of caspofungin is not of importance. Additional advantages of the new method are that only a small quantity of serum (5 microL) is needed and that the method is very specific.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Instrumentation
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...