Related Experiment Video
Updated: Aug 21, 2026

Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Enzymatic determination of urea in milk by sequential injection with spectrophotometric and conductometric detection
M J Reis Lima1, Sílvia M V Fernandes, António O S S Rangel
1Escola Superior de Biotecnologia, Universidade Católica Portuguesa, R. Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal.
Abstract:
In this work, an analytical system based on the coupling of gas diffusion separation and sequential injection analysis for urea determination in milk is presented. A versatile manifold that could simultaneously be used for either spectrophotometric or conductometric detection was constructed. The sample and urease solution are sequentially aspirated into the holding coil and sent to a thermoreactor, where urea is enzymatically hydrolyzed by urease and converted into ammonium. This stream merges an alkaline solution at a confluence point where ammonia is formed. Ammonia diffuses through a hydrophobic membrane and modifies the bromothymol blue indicator color, when spectrophotometric detection is used, or changes the conductance of a boric acid solution acceptor stream, when conductometric detection is used. This methodology was applied to the determination of urea in 18 milk samples and the results were statistically comparable with those furnished by the enzymatic recommended procedure. The detection limits were 2.6 x 10(-4) and 2.8 x 10(-5) mol L(-1) for conductometric and spectrophotometric detection, respectively. Repeatability (relative standard deviation, RSD) was better than 3.7% and 2.6% for conductometric and spectrophotometric detection, respectively.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Indirect and Alkalimetric Titration
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
