Operational variables in high-performance liquid chromatography-electrospray ionization mass spectrometry of peptides
Wolfgang Walcher1, Hansjörg Toll, Arnd Ingendoh
1Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens-University, A-6020 Innsbruck, Austria.
Abstract:
Capillary reversed-phase high-performance liquid chromatography (RP-HPLC) utilizing monolithic poly(styrene-divinylbenzene) columns was optimized for the coupling to electrospray ionization mass spectrometry (ESI-MS) by the application of various temperatures and mobile phase additives during peptide and protein analysis. Peak widths at half height improved significantly upon increasing the temperature and ranged from 2.0 to 5.4 s for peptide and protein separations at 70 degrees. Selectivity of peptide elution was significantly modulated by temperature, whereas the effect on proteins was only minor. A comparison of 0.10% formic acid (FA), 0.050% trifluoroacetic acid (TFA), and 0.050% heptafluorobutyric acid (HFBA) as mobile phase additives revealed that highest chromatographic efficiency but poorest mass spectrometric detectabilities were achieved with HFBA. Clusters of HFBA, water, and acetonitrile were observed in the mass spectra at m/z values >500. Although the signal-to-noise ratios for the individual peptides diverged considerably both in the selected ion chromatograms and extracted mass spectra, the average mass spectrometric detectabilities varied only by a factor of less than 1.7 measured with the different additives. Limits of detection for peptides with 500 nl sample volumes injected onto a 60 mm x 0.20 mm monolithic column were in the 0.2-13 fmol range. In the analysis of hydrophobic membrane proteins, HFBA enabled highest separation selectivity at the cost of lower mass spectral quality. The use of 0.050% TFA as mobile phase additive turned out to be the best compromise between chromatographic and mass spectrometric performance in the analysis of peptides and proteins by RP-HPLC-ESI-MS using monolithic separation columns.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...