Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
Published on: May 26, 2019
Linear accelerator output variability
1Department of Radiation Therapy, Wellington School of Medicine and Health Sciences, University of Otago, Wellington, New Zealand. ivan.luketina@wnmeds.ac.nz
Abstract:
The Wellington Cancer Centre is equipped with two matched linear accelerators (Varian 2100CD) linear accelerators (identified as SN1027 and SN42). Each morning, before treatments commence, a radiation therapist carries out an output constancy check of the radiation output and every fortnight a physicist measures, in a phantom, the delivered radiation dose to check on the machine calibration. The daily output checks have been recorded into a database (Argus QA for Radiation Oncology) since August 1997 and in June 1998 the fortnightly calibration measurements were added. The information in the database, up to April 2003, has been analysed to consider the quality of the daily constancy checks as compared with the fortnightly calibration measurements and whether the data contains useful information on machine performance. After allowance for the effects of machine recalibration the fortnightly calibration measurements had an average standard deviation of 0.4% and the daily constancy checks 0.8%. The daily constancy checks had a greater number of large deviations than would be expected assuming a normal distribution and were not a good predictor of the need for a recalibration. The fortnightly calibration measurements with a much lower spread give a reliable indication of the need for a recalibration allowing the adoption of a +/- 1% tolerance. Over the period analysed one accelerator (SN42) was relatively stable with the output generally drifting between +/- 1% while the other (SN1027) had a consistent increase in the average output of about 2.5% per year.
Related Concept Videos
Average Acceleration
Acceleration Vectors
Linear Momentum in Control Volume
Accelerators
The effectiveness of calcium chloride can...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Variation in Acceleration due to Gravity near the Earth's Surface
The difference between the true and apparent weights is proportional to the square of the Earth's angular speed. Since the...