Related Experiment Video
Updated: Aug 4, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Preliminary results of 3D dose calculations with MCNP-4B code from a SPECT image
M Rodríguez Gual1, F F Lima, R Sospedra Alfonso
1Instituto Superior de Ciencias y Tecnologías Nucleares, Ciudad Habana, Cuba. mrgual@yahoo.es
Abstract:
Interface software was developed to generate the input file to run Monte Carlo MCNP-4B code from medical image in Interfile format version 3.3. The software was tested using a spherical phantom of tomography slides with known cumulated activity distribution in Interfile format generated with IMAGAMMA medical image processing system. The 3D dose calculation obtained with Monte Carlo MCNP-4B code was compared with the voxel S factor method. The results show a relative error between both methods less than 1 %.