Isokinetic dynamometers have been measured for torque and force reliability in the past, but little research has been performed on rate of velocity development (RVD) measures. The purpose of this study was to determine the reliability of RVD measures on an isokinetic device at slow and fast speeds. Twenty volunteers performed 5 repetitions of concentric knee extension at 1.04 and 4.18 rad.s(-1) on a Kin-Com isokinetic dynamometer. Each subject was identically posttested 7 days later. Data were separated into 3 velocity range-of-motion (ROM) phases of RVD, load range (LR), and deceleration (DCCROM). Analyses of variance (ANOVAs) were performed to analyze the mean data between day 1 and day 2, while intraclass correlation coefficients (ICCs) were performed for reliability. Results at 1.04 rad.s(-1) demonstrated a low but significant (p < 0.05) ICC value (0.58) only for LR, while at 4.18 rad.s(-1) RVD (0.87), LR (0.83), and DCC (0.55) all exhibited significant ICC values. Percent error for high-speed testing ranged from 1.4-3.19%. No variable exhibited a significant mean difference between testing days. These results collectively point to moderate to high phase reliability for RVD measures at fast speeds of testing, while the slow speed showed very low reliability. Therefore, care should be exercised at slow speeds when comparing RVD measures from test to test.
More Related Videos
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
07:44Construction of Constant-Load (Isotonic) and Constant-Velocity (Isokinetic) Torque-Velocity-Power Profiles In vivo for the Rat Plantar Flexors
Published on: October 3, 2025
Related Concept Videos
Average and Instantaneous Velocity Vectors
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Distance Problem