Related Experiment Video
Updated: Aug 19, 2026

Ultrasonic Assessment of Myocardial Microstructure
Published on: January 14, 2014
Ultrasound tissue characterization by integrated backscatter for analyzing Fluorouracil induced myocardial damage
Ceyhun Ceyhan1, Nezih Meydan, Sabri Barutca
1Department of Cardiology, School of Medicine, Adnan Menderes University, Aydin, Turkey. ceyhunceyhan@yahoo.com
Background:
5-Fluorouracil (5-FU) cardiotoxicity is a well-known clinical phenomenon whose pathophysiology remains controversial. Cyclic variation of integrated backscatter (CVIBS) assesses acoustic properties of myocardium that may reflect both contractility and structural changes. The aim of this study was to evaluate CVIBS alterations in cancer patients under high-dose leucovorin and infusional 5-FU (HDLV5FU) chemotherapy.
Method:
We prospectively evaluated 37 cancer patients under HDLV5FU treatment. Transthoracic echocardiography and CVIBS were performed at the 0th, 48th hours, and on day 15 of the first cycle. The parasternal long-axis view was preferred to obtain the image of integrated backscatter and mainly two regions of interest--interventricular septum (IVS) and posterior wall (PW)--were used.
Results:
Clinical cardiotoxicity was observed in two patients. No significant differences were detected in pre- and posttreatment conventional echocardiography evaluations. However, both the IVS (9.3 +/- 1.0 to 8.1 +/- 1.2 dB, P < 0.001) and PW (9.1 +/- 0.7 to 7.8 +/- 0.9 dB, P < 0.001) CVIBS values significantly decreased in all patients. All values were returned to pretreatment levels (9.2 +/- 0.9 dB in the CVIBS-IVS and 8.9 +/- 0.6 dB in CVIBS-PW, respectively) on day 15 after the treatments.
Conclusion:
This study suggests that HDLV5FU may cause acute transient alterations in CVIBS values in the absence of clinical symptoms and signs of cardiotoxicity. The clinical value of CVIBS should be further studied in patients receiving 5-FU-based therapy.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...

