Characteristics of the normative database for the Humphrey matrix perimeter
Andrew John Anderson1, Chris A Johnson, Murray Fingeret
1Discoveries in Sight, Devers Eye Institute, Portland, Oregon, USA.
Purpose:
The Humphrey Matrix (Carl Zeiss Meditec, Dublin CA; Welch-Allyn, Skaneateles, NY) is a high-spatial-resolution perimeter that uses frequency-doubling stimuli. It incorporates an efficient test strategy that assumes that age, eccentricity, and test procedure type have only small effects on sensitivity. The results used to create the normative database for the perimeter were examined, to see whether these assumptions were met and to examine the form of the normative data.
Method:
Visual fields were measured (Matrix 30-2, 24-2, 10-2 and Macula patterns) in >275 subjects judged to be normal by a battery of clinical procedures. The right eye was always tested first.
Results:
Sensitivity decreased by approximately 0.7 dB per age decade across all eccentricities; sensitivity decreased with eccentricity, typically by <5 dB at the most peripheral points tested. Although there was no systematic difference in sensitivity between the 30-2 and 24-2 tests, the Macula test sensitivities were typically 1 dB higher than for the 10-2 test. Sensitivity in the left eye was slightly lower than in the right, with the difference being significantly greater in the temporal visual field. In most test locations, the 95% confidence interval of normal sensitivity was approximately 6 dB below the median sensitivity.
Conclusions:
The performance of the test strategy in the Matrix perimeter is appropriately matched to the response characteristics of the normal population. The finding of a spatially nonuniform difference in sensitivity between left and right eyes is attributable to light-adaptation differences between the eyes. This effect is accounted for in the perimeter's normative database.
Related Concept Videos
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first column of the Routh...
Central Limit Theorem
The sample size, n, that...
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
The Bell Curve
This pattern applies to many human characteristics beyond intelligence, such as height. For example, if you...
Expected Frequencies in Goodness-of-Fit Tests
The Representativeness Heuristic