Evaluation of four mass spectrometric methods for the gas chromatographic analysis of polychlorinated n-alkanes
Zdenek Zencak1, Anders Borgen, Margot Reth
1Organic Analytical Chemistry, University of Basel, Neuhausstr. 31, 4057 Basel, Switzerland.
Abstract:
The suitability of four mass spectrometric methods for the gas chromatographic analysis of polychlorinated n-alkanes (PCAs, also called chlorinated paraffins) was evaluated and compared using spiked and fish liver samples. Electron ionization tandem mass spectrometry (EI-MS/MS) as well as electron capture negative ionization (ECNI) combined with low and high resolution mass spectrometry and CH4/CH2Cl2-negative ion chemical ionization (NICI) low resolution mass spectrometry were investigated. All methods showed an accuracy of <21% for the analysis of spiked fish samples. However, the analysis of real samples showed deviations of up to 46% between the four mass spectrometric methods. The influence of the selected reference standard on quantification was also evaluated. The use of a quantification standard with a degree of chlorination deviating from that of the sample can result in differences of > 100% for the ECNI methods. EI-MS/MS and CH4/CH2Cl2-NICI led to errors of maximum 17% and 33%, respectively, independent from the degree of chlorination of the used reference standard.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
Mass Spectrometry: Long-Chain Alkane Fragmentation
Mass Spectrometry: Branched Alkane Fragmentation
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Alkyl Halide Fragmentation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...