Application of surface ionization methods for highly sensitive and selective analysis of benzodiazepine derivatives

Usman Khasanov1, Utkur Rasulev, Dilshod Usmanov

  • 1Arifov Institute of Electronics, Akademgorodok, 700125 Tashkent, Uzbekistan. ariel@ariel.uzsci.net

Related Concept Videos

High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene01:13

Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene

Bromination and chlorination of aromatic rings by electrophilic aromatic substitution reactions are easily achieved, but fluorination and iodination are difficult to achieve. Fluorine is so reactive that its reaction with benzene is difficult to control, resulting in poor yields of monofluoroaromatic products. To address this, Selectfluor reagent is used as a fluorine source in which a fluorine atom is bonded to a positively charged nitrogen.
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...