Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
High-speed gas chromatography with direct resistively-heated column (ultra fast module-GC)-separation measure (S) and
C Bicchi1, C Brunelli, C Cordero
1Dipartimento di Scienza e Tecnologia del Farmaco-Università degli Studi di Torino, Via Pietro Giuria 9, I-10125 Torino, Italy. carlo.bicchi@unito.it
Abstract:
The influence of GC speed on the separation capability of a chromatographic system is reported measuring a series of parameters including separation measure (S), peak capacity (n), peak width (w), analysis time, t(b) (determined on the last eluting compound) and separation measure/analysis time ratio (S/t(b)) determined by analyzing a bergamot essential oil sample and a standard mixture of pesticides. Conventional GC, fast GC (with 10 m (FGC10) and 5 m (FGC5) narrow-bore columns), and direct resistively-heated ultra fast module-GC (UFM-GC) were the GC speed approaches used. The influence of different heating rates with a constant flow for FGC5, FGC 10, and UFM-GC and with variable flows for UFM-GC on S, n, w, S/t(b), and t(b) was also studied. The results of this study show that: (a) separation capability of the chromatographic system (i.e. S and n) and analysis time depend on the GC approaches. Within each GC approach, S and n and analysis time depend on the heating rates, although to a different extent, and S and n decrease much less than the gain in analysis time, in particular when fast heating rates are applied; (b) in UFM-GC, the loss of separation capability with heating rate can also be partially compensated by the choice of an appropriate flow rate that, within each heating rate, may contribute to increase S while reducing t(b); (c) within a specific GC approach, the chromatographic system (column and stationary phase) and conditions (heating and flow rates) must be such to achieve a suitable S-value when two analytes must be separated with a given resolution in a minimum analysis time.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...