Related Experiment Video
Updated: Aug 17, 2026

Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Simultaneous optimization of the resolution and analysis time in micellar liquid chromatography of phenyl
Fariba Safa1, Mohammad Reza Hadjmohammadi
1Department of Chemistry, Mazandaran University, P.O. Box 453, Babolsar, Iran.
Abstract:
The chemometrics approach was applied for simultaneous optimization of resolution and analysis time of nine phenyl thiohydantoin amino acids in micellar liquid chromatography. Derringer's desirability function, a multi-criteria decision making method, was tested for the evaluation of the two different chromatographic performance goals. The effect of five experimental parameters on a chromatographic response function formed using two sigmoidal desirability functions was investigated. The sigmoidal functions were used to transform the optimization criteria, resolution and analysis time, into the desirability values. The factors studied were the concentration of sodium dodecyl sulfate, alkyl chain length of the alcohol used as the organic modifier, organic modifier content, mobile phase pH and temperature. The experiments were performed according to a face-centred cube response surface experimental design to map the chromatographic response surface. Then, calculated chromatographic response functions were fitted to a polynomial model. The obtained regression model was characterized by both descriptive and predictive ability (R2 = 0.988 and R(2)cv = 0.973). The model was verified, as good agreement was observed between the predicted and experimental values of the chromatographic response function in the optimal condition. Based on the results of the study, combination of response surface mapping with Derringer's desirability function allows to predict the best operating condition in micellar liquid chromatography of phenyl thiohydantoin amino acids with respect to resolution and analysis time.
More Related Videos
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Elution Process