Effect of anionic ion-pairing reagent concentration (1-60 mM) on reversed-phase liquid chromatography elution
M Shibue1, C T Mant, R S Hodges
1Department of Biochemistry and Molecular Genetics, University of Colorado Health Sciences Center at Fitzsimons, Aurora, CO 80045, USA.
Abstract:
The homologous series of volatile perfluorinated acids-trifluoroacetic acid (TFA), pentafluoropropionic acid (PFPA) and heptafluorobutyric acid (HFBA)--continue to be excellent anionic ion-pairing reagents for reversed-phase high-performance liquid chromatography (RP-HPLC) after more than two decades since their introduction to this field. It was felt that a thorough, step-by-step re-examination of the effects of anionic ion-pairing reagents over a wide concentration range on RP-HPLC peptide elution behaviour is now due, particularly considering the continuing dominance of such reagents for peptide applications. Thus, RP-HPLC was applied over a range of 1-60 mM phosphoric acid, TFA, PFPA and HFBA to two mixtures of 18-residue synthetic peptides containing either the same net positive charge (+4) or varying positive charge (+1, +2, +3, +4). Peptides with the same charge are resolved very similarly independent of the ion-pairing reagent used, although the overall retention times of the peptides increase with increasing hydrophobicity of the anion: phosphate < TFA- < PFPA- < HFBA-. Peptides of differing charge move at differing rates relative to each other depending on concentration of ion-pairing reagents. All four ion-pairing reagents increased peptide retention time with increasing concentration, albeit to different extents, again based on hydrophobicity of the anion, i.e., the more hydrophobic the anion, the greater the increase in peptide retention time at the same reagent concentration. Interestingly, phosphoric acid produced the best separation of the four-peptide mixture (+1 to +4 net charge). In addition, concentrations above 10 mM HFBA produced a reversal of the elution order of the four peptides (+1 < + 2 < + 3 < + 4) compared to the elution order produced by the other three reagents over the entire concentration range (+4 < + 3 < + 2 < + 1).
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Related Concept Videos
Basicity of Heterocyclic Aromatic Amines
Extraction: Advanced Methods
Ion Exchange
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography